ABB · Moulded Case Circuit Breakers
SACE Tmax XT IEC
ABB moulded-case circuit breakers organized by the SACE Tmax XT, Formula, Tmax T and specialist platforms.
This page is informational and does not build an order number online. Confirm the final configuration against the complete ABB designation and manufacturer documentation.
- Brand
- ABB
- Category
- Moulded Case Circuit Breakers
SERIES OVERVIEW
Primary identification parameters
- Series
- SACE Tmax XT IEC
- Type
- moulded-case circuit breakerMCCB
- Current range
- up to 1600A
- Standards / voltage
- IEC 60947-2; model-dependent至690Vac及特殊应用
- Mounting
- fixed / plug-in / withdrawable
- Trip unit
- TMD/TMA, Ekip Dip, Ekip Touch, MCP/MCS
- Key capability
- 七种主要框架XT1–XT7; 系列up to 分断能力按框架可达高等级
TECHNICAL DATA · 50 ROWS
SACE Tmax XT IEC 基础电流与配置矩阵
额定电流行用于检索, 不代表每一性能等级 and 脱扣器均可任意组合.
| No. | Frame | Base rated current | Frame limit | Poles | Mounting | Available trip units | Performance level | Typical applications |
|---|---|---|---|---|---|---|---|---|
| 1 | XT1 | 16 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 2 | XT1 | 20 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 3 | XT1 | 25 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 4 | XT1 | 32 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 5 | XT1 | 40 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 6 | XT1 | 50 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 7 | XT1 | 63 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 8 | XT1 | 80 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 9 | XT1 | 100 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 10 | XT1 | 125 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 11 | XT1 | 160 A | 160A | 1/2/3/4P(version-dependent) | fixed/plug-in | TMD; MCP/MCS | B/C/N/S/H等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 12 | XT2 | 16 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 13 | XT2 | 20 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 14 | XT2 | 25 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 15 | XT2 | 32 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 16 | XT2 | 40 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 17 | XT2 | 50 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 18 | XT2 | 63 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 19 | XT2 | 80 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 20 | XT2 | 100 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 21 | XT2 | 125 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 22 | XT2 | 160 A | 160A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/C/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 23 | XT3 | 63 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 24 | XT3 | 80 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 25 | XT3 | 100 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 26 | XT3 | 125 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 27 | XT3 | 160 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 28 | XT3 | 200 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 29 | XT3 | 225 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 30 | XT3 | 250 A | 250A | 3/4P | fixed/plug-in | TMD; MCP/MCS | 常用N/S等级, 按目录 | distribution / motor / generator等, 按脱扣器 |
| 31 | XT4 | 160 A | 250A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 32 | XT4 | 200 A | 250A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 33 | XT4 | 250 A | 250A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 34 | XT5 | 300 A | 630A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 35 | XT5 | 400 A | 630A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 36 | XT5 | 500 A | 630A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 37 | XT5 | 600 A | 630A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 38 | XT5 | 630 A | 630A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip/Touch, MCP/MCS | B/N/S/H/L/V等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 39 | XT6 | 600 A | 1000A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip, MCP/MCS | N/S/H/L等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 40 | XT6 | 630 A | 1000A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip, MCP/MCS | N/S/H/L等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 41 | XT6 | 800 A | 1000A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip, MCP/MCS | N/S/H/L等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 42 | XT6 | 1000 A | 1000A | 3/4P | fixed/plug-in/withdrawable | TMA, Ekip Dip, MCP/MCS | N/S/H/L等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 43 | XT7 | 800 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | S/H/L等高性能等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 44 | XT7 | 1000 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | S/H/L等高性能等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 45 | XT7 | 1250 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | S/H/L等高性能等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 46 | XT7 | 1600 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | S/H/L等高性能等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 47 | XT7M | 800 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | 带储能机构; 等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 48 | XT7M | 1000 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | 带储能机构; 等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 49 | XT7M | 1250 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | 带储能机构; 等级按目录 | distribution / motor / generator等, 按脱扣器 |
| 50 | XT7M | 1600 A | 1600A | 3/4P | fixed/withdrawable | Ekip Dip/Touch, MCP/MCS | 带储能机构; 等级按目录 | distribution / motor / generator等, 按脱扣器 |
TECHNICAL DATA · 20 ROWS
ABB MCCB 脱扣器, 操作与通信附件
完整BOM必须同时确认框架, 安装形式, 控制电压 and 附件数量.
| Category | Model / function | Protection / function | 适用框架 | Key features | Procurement cautions |
|---|---|---|---|---|---|
| 热磁脱扣 | TMD | fixed或有限可调长延时+瞬时 | XT1/XT3及部分框架 | 简单, 无需辅助电源 | 额定电流 and 瞬时倍数随完整型号 |
| 热磁脱扣 | TMA | 可调过载 and 短路 | XT2/XT4/XT5/XT6及Tmax T | 适合AC/DC部分应用 | 核对可调范围与环境降额 |
| 电子脱扣 | Ekip Dip LI/LSI/LSIG | distribution保护 | XT2/XT4/XT5/XT6/XT7 | DIP设置, 电子保护 | 版本与框架兼容性必须确认 |
| 电子脱扣 | Ekip Touch LSI/LSIG | 保护, 测量, 告警 and 通信 | XT2/XT4/XT5/XT7 | 触摸界面, Bluetooth及数字功能 | 需确认Ekip Supply/Cartridge and 许可 |
| 电机保护 | MCP / MCS | 磁保护或motor回路保护 | XT1–XT7model-dependent | 配合接触器 and 过载保护 | 必须按协调表选型 |
| 电机保护 | Ekip M Dip / Ekip M Touch | 电机过载, 短路, 缺相等 | 高级XT框架 | 电子电机保护 | 电机额定电流, 起动等级 and 接触器需同时确认 |
| 旧电子脱扣 | PR221DS / PR222DS/P / PR223DS | Tmax Tdistribution保护 | T4/T5/T6 | DIP/电子功能 | 仅用于legacy平台 and 备件识别 |
| 旧电子脱扣 | PR231/P / PR232/P / PR331/P / PR332/P | T7/T8保护与计量 | T7/T8 | 不同等级的保护 and 显示 | 需核对传感器, 固件 and 附件 |
| 操作附件 | SOR / SOR-C | 分励脱扣 | XT1–XT4等 | 多种AC/DC控制电压 | 线圈电压 and fixed/plug-in/withdrawable版本必须一致 |
| 操作附件 | UVR / UVR-C | 欠压脱扣 | 按框架 | 欠压联锁/保护 | 电压, 延时 and 安装形式需确认 |
| 辅助触点 | AUX / AUX-C / 2Q 2SY 1S51 | 合分位, 脱扣 and 报警 | 按框架 | 内部或预接线版本 | 触点数量 and 功能代码逐项确认 |
| 电动操作 | MOE / MOD / motor operator | 远程合分闸/储能 | 按框架 | 不同框架机构不同 | 控制电压, 操作逻辑 and 附件空间需确认 |
| 手柄 | RHD / RHE | 直接/延伸旋转手柄 | XT系列 | 门联锁 and 隔离功能 | 轴长, 门深 and IP等级需确认 |
| 通信 | Ekip Com Modbus / Ethernet / Profibus / Profinet | 远程状态, 测量 and 控制 | Ekip Touch配置 | 多协议集成 | 需要兼容的Ekip模块 and 辅助电源 |
| 扩展 | Ekip Cartridge / Ekip Supply | 外部附件 and 辅助供电 | Ekip Touch | DIN导轨安装, 连接外部模块 | 控制电压 and 模块组合需核对 |
| 测量 | Ekip Measuring / Measuring Pro | 电压, 功率, 电能 and 电能质量 | Ekip Touch | 高级测量 | 精度, 采样 and 外部电压连接model-dependent |
| 传感器 | External neutral | 3P系统中性线测量/保护 | 部分Ekip框架 | 外置N传感器 | 额定电流, 线长 and 中性线比例需匹配 |
| 机械附件 | plug-in底座 / withdrawablefixed部分 | 安装 and 隔离 | 按框架 | 便于维护 and 更换 | 不可只报价移动本体 |
| 端子附件 | 前接/后接/扩展端子/多电缆端子 | 母排 and 电缆连接 | 按框架 | 适应不同柜体 | 载流量, 相间距 and 防护罩需确认 |
| 联锁 | 钥匙/机械/电气联锁 | 两台或多台断路器互锁 | 按框架 | ATS/母联应用 | 联锁逻辑 and 安装尺寸需工程确认 |
TECHNICAL DATA · 10 ROWS
ABB MCCB 型号层级与代码示例
不要依据示例手工生成1SDA订货号.
| Example | Product level | Meaning | 是否可直接下单 | 还需确认 |
|---|---|---|---|---|
| XT2 160 | 框架+电流 | XT2框架, 160A等级 | 否 | 性能等级, 极数, 安装, 脱扣器 and 附件 |
| XT4H 250 | 框架+分断等级+电流 | XT4 H级, 250A基础描述 | 否 | Icu对应电压, 脱扣器, 极数 and 端子 |
| XT5 630 Ekip Touch LSIG | 基础配置描述 | 630A框架 and 高级脱扣器 | 否 | 商业1SDA代码, 安装形式, 附件电压 |
| F / P / W | 安装描述 | fixed / plug-in / withdrawable(实际字母按目录) | 否 | 底座, fixed部分 and 端子 |
| TMD / TMA | 热磁脱扣器 | fixed或可调热磁保护 | 配置项 | 额定电流 and 瞬时设定 |
| Ekip Dip / Touch | 电子脱扣器平台 | 保护, 测量 and 通信等级不同 | 配置项 | LI/LSI/LSIG, 辅助电源 and 模块 |
| A2 250 | Formula基础型号 | A2框架, 250A上限 | 否 | 极数, 额定电流 and 完整1SDA代码 |
| T7 1600 PR332/P | legacyTmax T描述 | T7, 1600A, PR电子脱扣器 | 否 | 安装, 极数, 端子 and 附件 |
| 1SDA……R1 | ABB商业参考号 | 完整可订购SKU | 通常是 | 销售国家, 生命周期 and 附件是否包含 |
| SOR/UVR/MOE | 附件代码 | 分励, 欠压 and 电动操作 | 附件SKU | 框架, 安装版本 and 控制电压 |
DATA AND IMAGE BASIS
Series-matched representative image
Technical values come from the supplied ABB workbook. The image is downloaded into this site's local assets and is not hotlinked.
- ABB official series reference
- exact-series-reference
Need help confirming the complete ABB designation?
The internal inquiry form carries ABB, category, series and key parameters automatically.