ZHIQI EQUIPMENT智启电器

Schneider Electric · Air Circuit Breaker

EasyPact MVS Air Circuit Breaker

Cost-focused LV power circuit breakers and switch-disconnectors covering multiple MVS frames and trip-system families.

This page supports range identification and project communication. Confirm the complete catalog number against the nameplate, ratings, poles, mounting, trip or control unit and auxiliary circuits.

EasyPact MVS — Schneider Electric
630–5000 A, family-dependent
Rated current
3P / 4P (family-dependent)
Poles
Fixed / drawout
Mounting
TS; ET; ETA; ETV
Trip systems

PRODUCT OVERVIEW

EasyPact MVS

Cost-focused LV power circuit breakers and switch-disconnectors covering multiple MVS frames and trip-system families.

EasyPact MVS is presented as one series. MVS1, MVS2, classic ET/ETA/ETV, Type T3 and DA1 are frame or application families within the detail page, not duplicate category cards. DA1 is identified separately because it is a DC switch-disconnector without overcurrent protection.

  • Rated current630–5000 A, family-dependent
  • Poles3P / 4P (family-dependent)
  • MountingFixed / drawout
  • Trip systemsTS; ET; ETA; ETV

PLATFORM STRUCTURE AND REVIEW POINTS

EasyPact MVS — Schneider Electric
  1. 01

    Range architecture

    MVS1 (TS) (630–1600 A); MVS2 (TS) (800–4000 A); MVS (ET / ETA / ETV) (630–4000 A); MVS Type T3 (800–5000 A); MVS DA1 (1600–4000 A)

  2. 02

    Breaking and withstand performance

    MVS1 (TS): C: 66 kA at 440 V; high selectivity 50 kA;MVS2 (TS): N: 50 kA (800–3200 A), 55 kA (4000 A); H: 66 kA at 440 V;MVS (ET / ETA / ETV): C / N / H performance levels; verify against the exact catalog number;MVS Type T3: New-energy application family; exact breaking rating depends on catalog configuration;MVS DA1: Icw 100 kA; DC switch-disconnector, not a protective ACB

  3. 03

    Poles and mounting

    3P / 4P;Per matched catalog number;4P;Fixed / drawout;Per matched catalog number

  4. 04

    Trip and control systems

    TS 2.0 / 5.0 / 2.0S / 5.0S / 6.0S;ET / ETA / ETV;ET / ETA;No overcurrent trip unit

TECHNICAL OVERVIEW

Product range
EasyPact MVS
Rated current
630–5000 A, family-dependent
Poles
3P / 4P (family-dependent)
Mounting
Fixed / drawout
Trip systems
TS; ET; ETA; ETV
Frames / branches
MVS1 (TS) (630–1600 A); MVS2 (TS) (800–4000 A); MVS (ET / ETA / ETV) (630–4000 A); MVS Type T3 (800–5000 A); MVS DA1 (1600–4000 A)

INQUIRY CHECKLIST

  • Complete designation and nameplate
  • System voltage and frequency
  • Rated current and breaking duty
  • Poles and connection arrangement
  • Fixed or drawout mounting
  • Trip or control unit
  • Auxiliary voltage and accessories
  • Quantity and application duty

APPLICATIONS

Industrial manufacturing facility

Industrial and process manufacturing

Main-distribution or critical-feeder protection for manufacturing and process facilities.

Commercial buildings and data centers

Commercial buildings and data centers

Low-voltage distribution where uptime and maintenance efficiency are important.

Power and public infrastructure

Power and public infrastructure

Distribution applications in energy, water, transport and large public facilities.

Renewable-energy infrastructure

Renewable energy and infrastructure

Confirm applicability against AC or DC system data, grounding arrangement and project duty.

RECOMMENDED SERIES RANGES

MVS1 (TS)

630–1600 A

Breaking / withstand
C: 66 kA at 440 V; high selectivity 50 kA
Poles
3P / 4P
Mounting
Fixed / drawout
Trip / control unit
TS 2.0 / 5.0 / 2.0S / 5.0S / 6.0S

MVS2 (TS)

800–4000 A

Breaking / withstand
N: 50 kA (800–3200 A), 55 kA (4000 A); H: 66 kA at 440 V
Poles
3P / 4P
Mounting
Fixed / drawout
Trip / control unit
TS 2.0 / 5.0 / 2.0S / 5.0S / 6.0S

MVS (ET / ETA / ETV)

630–4000 A

Breaking / withstand
C / N / H performance levels; verify against the exact catalog number
Poles
3P / 4P
Mounting
Fixed / drawout
Trip / control unit
ET / ETA / ETV

MVS Type T3

800–5000 A

Breaking / withstand
New-energy application family; exact breaking rating depends on catalog configuration
Poles
Per matched catalog number
Mounting
Per matched catalog number
Trip / control unit
ET / ETA

MVS DA1

1600–4000 A

Breaking / withstand
Icw 100 kA; DC switch-disconnector, not a protective ACB
Poles
4P
Mounting
Per matched catalog number
Trip / control unit
No overcurrent trip unit

These values identify the range. Confirm final configuration and full ordering information against the nameplate, system data, mounting, cradle interfaces and auxiliary circuits.